Addressable Modbus Registers

You can use Modbus to access information about the SMART System's status and its bat activity alarms. You can also alter some parameters of bat activity alarms using Modbus messages.

Function Code (decimal) Address (decimal)

Description (where M is a digit 1-8 for Alarm M) and X is any digit 0-9.

Unit
2 1 0000M Alarm M bat pass alarm (1 = alarm present, 0 = no alarm)
2 1 0001M Alarm M bat pulse alarm (1 = alarm present, 0 = no alarm)
2 1 0002X Reserved for customization
3/6/16 4 000M1 Pass Alarm M number of rolling seconds for bat pass alarm period
3/6/16 4 000M2 Pass Alarm M minimum number of bat passes per period to set alarm (high water)
3/6/16 4 000M3 Pass Alarm M maximum number of bat passes per period to clear alarm (low water)
3/6/16 4 000M4 Pulse Alarm M number of rolling seconds for bat pulse alarm period
3/6/16 4 000M5 Pulse Alarm M minimum number of bat pulses per period to set alarm (high water)
3/6/16 4 000M6 Pulse Alarm M maximum number of bat pulses per period to clear alarm (low water)
3/6/16 4 0009X Reserved for customization
4 3 00001 Disk utilization (0-100%) %
4 3 00002 Memory utilization (0-100%) %
4 3 00003 CPU utilization (0-100%) %
4 3 00004 Voltage 0.1 V
4 3 000M1 Pass Alarm M bat pass event counter (modulo 65536)
4 3 000M2 Pass Alarm M bat pass events per period
4 3 000M3 Pass Alarm M seconds since most recent pass event (up to 65535) s
4 3 000M4 Pass Alarm M bat pass alarm counter (modulo 65536)
4 3 000M5 Pulse Alarm M bat pulse event counter (modulo 65536)
4 3 000M6 Pulse Alarm M bat pulses per period
4 3 000M7 Pulse Alarm M seconds since most recent pulse event (up to 65535) s
4 3 000M8 Pulse Alarm M bat pulse alarm counter (modulo 65536)
4 3 00M01 Pass Alarm M most recent value N (number of pulses in pass)
4 3 00M02 Pass Alarm M most recent value Fc (characteristic frequency) 10 Hz
4 3 00M03 Pass Alarm M most recent value Sc (characteristic slope) octaves per second (OPS)
4 3 00M04 Pass Alarm M most recent value Fmax (maximum frequency) 10 Hz
4 3 00M05 Pass Alarm M most recent value Fmin (minimum frequency) 10 Hz
4 3 00M06 Pass Alarm M most recent value Fmean (mean frequency) 10 Hz
4 3 00M07 Pass Alarm M most recent value TBC (time between calls) 0.1 ms
4 3 00M08 Pass Alarm Mmost recent value Fk (frequency of knee) 0.1 ms
4 3 00M09 Pass Alarm M most recent value Tk (time of knee) 0.1 ms
4 3 00M10 Pass Alarm M most recent value S1 (initial slope) OPS
4 3 00M11 Pass Alarm M most recent value Tc (time of characteristic) 0.1 ms
4 3 00M12 Pass Alarm M most recent value Dur (pulse duration) 0.1 ms
4 3 009XX Reserved for customization